INSTALLATION

THE INSTALLATION OF THIS APPLIANCE MUST BE IN ACCORDANCE WITH:

1) All applicable local codes, or in the absence of local codes;

2) i) Canada: must conform to current National Standard CAN/CGA B149.1&.2 -

natural gas/propane installation code.

ii) U.S.A.: must conform to national Fuel Gas Code, ANSI Z223.1, 1988 or latest

edition.

WARNING!

DO NOT operate this appliance under overhead, unprotected construction. This
appliance shall be used only in a well ventilated space and shall not be used in a building,
garage, or any other enclosed area.

Minimum clearance to adjacent combustible materials:

• 12 inches from side(s)

• 24 inches from back (See Fig. 1 pg. 3.)

• This appliance is suitable for use on combustible floors.

• Always level your MCB front to back & side to side.

• Always keep the area surrounding your charbroiler clear of all combustible materials,

gasoline, or other flammable liquids.

• Use your charbroiler OUTDOORS in a well-ventilated space, preferably 10 ft. from

dwellings or outbuildings.

• Casters must be locked when appliance is in operation.

CAUTION: FOR FIXED FUEL SUPPLY SYSTEMS

RE: PRESSURE TESTS

1. The appliance and its individual shut-off valve must be disconnected from the gas

supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 psi. (3.45 kPa).

2. The appliance must be isolated from the gas supply piping system by closing it’s

individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi. (3.45kPa).