Operating Limits

Power Output

The inverter can deliver 2500 watts for about 60 minutes.
The inverter must cool for 15 minutes before it can
resume operation at 2500 watts. Note: The wattage
rating applies to resistive loads.

The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps,
and other motor-operated equipment require very high
surge currents to start. The inverter may not be able
to start some of these motors even though their rated
current draw is within the inverter’s limits. The inverter
will normally start single phase induction motors rated
at one-half HP or less.

Input Voltage

The inverter will operate from input voltage ranging
from 10 volts to 15 volts. Optimum performance will
occur when the voltage is between 12 volts and 14 volts.
If the voltage drops below 10.5V+/- 0.3V, an audible low
battery warning will sound. The inverter will shut down if
the input voltage drops below 9.5V+/- 0.3V. This protects
the battery from being over-discharged. It will restart
when the input voltage exceeds 12V+/- 0.3V.

The inverter will also shut down if the input voltage
exceeds 15.5V +/- 0.5V. This protects the inverter
against excessive input voltage. Although the inverter
has protection against over-voltage, it may still be
damaged if the input voltage were to exceed 16 volts.

High Temperature

Over Temperature Protection –
If the internal inverter temperature
rises above the alarm threshold,
the meter will flash as shown, an
alarm will sound to indicate Over
Temperature Protect, and the unit
will continue to operate. If the
internal temperature rises to 40ºC
(104ºF), the inverter will shut down
to protect itself, the meter will
flash as shown and the alarm will
continue to sound.

NOTE Internal inverter temperature
can rise due to being operated in a
high heat environment or due to the
fan or vents being blocked during
operation (even in relatively cool
outside air).

To restore normal operation, turn
the unit Off and allow it to cool.
The inverter will automatically
return to normal operation after
it has cooled.

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Operating Indicators

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Operation

10276_CPI2575_PH1 8/20/07 2:33 PM Page 18

Advertising