Chapter 2, Control description – Drawmer 1968 Dual Ch Tube Compressor User Manual

Page 6

Advertising
background image

6

DRAWMER 1968

MkII

O

PERATOR’S

M

ANUA

L

CONTROL DESCRIPTION

Threshold:

Determines the input level above which gain reduction will be applied and may be
set in the range -30dB to infinity. Because the compression system is based on
the Soft Knee principle, the onset of compression is progressive, so no Ratio
control is necessary.

Big:

Makes the compressor side chain less sensitive to low bass frequencies, so
reducing the ducking effect caused by bass energy and effectively boosting the
bass output

, the 'Bigger' option more so.

Attack:

Six switchable Attack settings are provided giving various settings. The actual
attack time is further modified by the release setting chosen

Attack Times:

1

2 ms

2

8 msec

3

15 msec

4

25 msec

5

30 msec

6

50 msec

Release:

There are three fixed Release times and a further three which are programme
dependent
. Switch settings 1 through to 3 provide progressively increasing
release times, while positions 4, 5 and 6 cause the release times to vary in a
manner which automatically adapts to the dynamics of the incoming signal, as
detailed below.

Release Times

1

100 ms

(Fixed)

2

500 msec

(Fixed)

3

1 sec

(Fixed)

4

Semi-Auto 200 ms to 2 sec Signal dependent

5

Semi-Auto 500 ms to 5 sec signal dependent

6

Automatic 1 sec to 10 sec signal dependent

CHAPTER 2