Chapter 3, General information, Data specification – Drawmer 1973 Three Band Stereo FET Compressor User Manual

Page 10: If a fault develops, Contacting drawmer, Three-band stereo fet compressor

Advertising
background image

10

DRAWMER 1973 O

PERATOR’S

M

ANUAL

CHAPTER 3

IF A FAULT DEVELOPS

For warranty service please call Drawmer Electronics Ltd. or
their nearest authorised service facility, giving full details of
the difficulty.

A list of all main dealers can be found on the Drawmer
webpages.

On receipt of this information, service or shipping instructions
will be forwarded to you.

No equipment should be returned under the warranty without
prior consent from Drawmer or their authorised representative.

For service claims under the warranty agreement a service
Returns Authorisation (RA) number will be issued.
Write this RA number in large letters in a prominent position
on the shipping box. Enclose your name, address, telephone
number, copy of the original sales invoice and a detailed
description of the problem.

Authorised returns should be prepaid and must be insured.

All Drawmer products are packaged in specially designed
containers for protection. If the unit is to be returned, the original
container must be used. If this container is not available, then
the equipment should be packaged in substantial shock-proof
material, capable of withstanding the handling for the transit.

CONTACTING DRAWMER

Drawmer Electronics Ltd., will be pleased to answer all
ap plic atio n qu estion s to enh an ce you r usag e of this
equipment. Please address correspondence to:

Drawmer (Technical Help line)
Coleman Street
Parkgate
Rotherham
S62 6EL
UK

Alternatively contact us by E-mail on :

for sales enquiries: [email protected]

or for technical issues: [email protected]

Further information on all Drawmer dealers, Authorised service
departments and other contact information can be obtained
from our web pages on:

http://www.drawmer.com

GENERAL INFORMATION

INPUT

Input Impedance

20k Ohms or greater

Maximum Input Level

+26dBu

OUTPUT

Output Impedance

100 Ohms

Maximum Output Level

+25dBu into 10k Ohms Load

FREQUENCY RESPONSE

<5Hz to 51kHz -1dB
<3Hz to 70kHz -3dB

CROSSTALK

< -80dB @ 1kHz

NOISE AT UNITY GAIN

with flat EQ response switched in circuit

W ideband

22Hz - 22kHz

AV

-82dB

-87dB

1973

THREE-BAND STEREO FET COMPRESSOR

DATA SPECIFICATION

% DISTORTION (THD & NOISE)

@ 1kHz

0dB (ref +4)

0.03%

10dB (ref +4)

0.07%

20dB (ref +4)

0.5%

POWER REQUIREMENTS

230Volt or 115V at 50-60hZ, 60VA

FUSE RATING

T250mA for 230Volt,
T500mA for 115Volt
Conforming to IEC 127-2

FUSE TYPE

20mm x 5mm, Class 3 Timed-Blo, 250Volt working

CASE SIZE

482mm (W) x 88mm (H) x 270mm (D)

WEIGHT

4.2Kgs

Advertising