4x Front Panel Outputs:
4x BNC output connectors mounted
on the front for ease of connectivity.

1

2

3

4

5

11

12

10

8

1

Display:
Blue/White liquid crystal display
with three switchable modes of
operation.

2

Display Mode:
Switch to control the mode of
display 2.

3

Input Source Select:
Selects either the AES or BNC rear
panel input source.

4

Clock Present LED’s:
Two led’s showing the Locked staus
of the AES and BNC inputs.

5

1x BNC Clock Input:
Input is selected using 4

6

1x BNC Clock Through:
BNC output with zero latency
loopthrough from BNC input.

7

BNC Termination Sensitivity:
Switch to alter the BNC termination
sensitivity between 75 Ohms and Hi
Z. This must be switched to Hi Z
when using Loop Through.

8

AES Termination Sensitivity:
Switch to alter the AES termination
sensitivity between 110 Ohms and
Hi Z. This must be switched to Hi Z
when using Loop Through.

9

1x AES Input:
Input is selected using 4

10

1x AES Through:
AES output with zero latency
loopthrough from AES input.

11

12

6

9

7

16x BNC Clock Outputs:
Buffered BNC wordclock outputs with
33 Ohms impedance.

FEATURES OVERLAY

The DMS-2 D-Clock is designed for standard 19" rack
mounting and occupies 1U of rack space. Avoid mounting
the unit directly above power amplifiers or power supplies
that radiate significant amounts of heat.
If the unit is to be used in a mobile situation, it is strongly
recommended that the rear of the unit is supported

in the carrying rack to avoid bending the front panel rack
mounting ‘ears’.
Always connect the mains earth to the unit. Use fibre or
plastic washers to prevent the front panel becoming marked
by the mounting bolts.

INSTALLATION

The unit will be supplied with a power cable suitable for
domestic power outlets in your country. For your own safety
it is important that you use this cable. The unit should
always be connected to the mains supply earth using this
cable.

Powered by a universal switch mode power supply, the
DMS-2 D-Clock operates from mains voltages between
85 - 250v, eliminating the need to make any changes when
touring and allowing the unit to remain fully operational
during large fluctuations in the mains power supply.