Operating instructions – ebm-papst G2E085-AA01-01 User Manual

Page 5

Advertising
background image

Operating instructions

G2E085-AA01-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E042-CA

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

fa

Valid for approval /
standard

CE

CE

Speed / min

-1

2350

2800

Power input / W

32

30

Current draw / A

0.15

0.14

Motor capacitor / µF

1

1

Capacitor voltage / VDB

400

400

Capacitor standard

P2 (CE)

P2 (CE)

Min. back pressure / Pa

0

0

Min. ambient temperature
/ °C

-25

-25

Max. ambient
temperature
/ °C

50

70

Starting current / A

0.2

0.2

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

0.85 kg

Size

85 mm

Surface of rotor

Partially cast in aluminium

Material of impeller

Sheet steel, hot-galvanised

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11064-5-9970 · Revision 82552 · Release 2014-05-08 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Advertising