3.2 Nominal data

Motor

M2E074-EI

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1950

2150

Power input / W

400

415

Current draw / A

1.75

1.82

Motor capacitor / µF

8

8

Capacitor voltage / VDB

400

400

Capacitor standard

P0 (CE)

P0 (CE)

Min. back pressure / Pa

0

250

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

40

30

Starting current / A

2.2

2

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.01

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

33.5

26.5

33.5

Efficiency grade N

44

37

44

Power input P

e

/ kW

0.22

Air flow q

v

/ m³/h

400

Pressure increase total p

sf

/ Pa

665

Speed n / min

-1

2705

Data established at point of optimum efficiency

3.4 Technical features

Mass

5.6 kg

Size

180 mm

Surface of rotor

Coated in black

Material of impeller

Sheet steel, galvanized

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position as per EN 60034-5

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10294-5-9970 · Revision 71118 · Release 2010-07-12 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com