Operating instructions – ebm-papst R3G190-RC05-03 User Manual

Page 7

Advertising
background image

Operating instructions

R3G190-RC05-03

Translation of the original operating instructions

4.4 Connection screen

No.

Conn.

Designation

Colour

Function / assignment

CON10 L

black

Power supply 230 VAC, 50-60 Hz, for voltage range refer to rating plate

CON11 N

blue

Neutral conductor

CON12 PE

green/
yellow

Protective earth

1

GND

blue

GND - Connection for control interface

2

0- 10V PWM

yellow

Control input 0 - 10 V or PWM, electrically isolated

3

10V/ max 1.1mA red

Voltage output 10 V / 1.1 mA, electrically isolated, not short-circuit-proof

4

Tach

white

Tach output: open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA

Item no. 51030-5-9970 · Revision 82598 · Release 2014-05-08 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Advertising