3.2 Nominal data

Motor

M6D138-LA

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

277

400

480

Connection

Δ

Δ

Y

Y

Frequency / Hz

50

60

50

60

Type of data definition

ml

ml

ml

ml

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

905

1080

905

1080

Power input / W

1570

2180

1570

2180

Current draw / A

5.92

6.6

3.42

3.8

Max. back pressure / Pa

170

150

170

150

Min. ambient temperature
/ °C

-40

-40

-40

-40

Max. ambient
temperature
/ °C

65

60

65

60

Starting current / A

22

24

13

14

Maximum safe operating
speed / min

-1

1230
@ 70 °C

1230
@ 70 °C

1230
@ 70 °C

1230
@ 70 °C

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

37.4

30.6

34.6

Efficiency grade N

42.8

36

40

Power input P

e

/ kW

1.38

Air flow q

v

/ m³/h

14570

Pressure increase total p

sf

/ Pa

128

Speed n / min

-1

920

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

24.2 kg

Size

800 mm

Surface of rotor

Cast in aluminium

Material of terminal box

PC / ABS plastic

Material of blades

Aluminium sheet insert, sprayed with PP
plastic

Number of blades

5

Blade angle

-5°

Direction of air flow

"V"

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F3-1

Mounting position

Any

Condensate discharge
holes

On rotor and stator sides

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60034-1 (2010); EN 61800-5-1; CE

Approval

CSA C22.2 Nr.100; EAC; UL 1004-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10594-5-9970 · Revision 82906 · Release 2014-05-08 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com