3.6. Output connections

The OUTPUTS section at the rear panel has screwable terminals (43, 44, 45, 46, 47, 48), one for

each amplifier.

The attenuation controls and the output configurations are described later in paragraph 3.7.
The cable which connects the speakers to the amplifier should be high quality and as short and

thick as possible. This is important when covering long distances; For up to 10m we recommend a cable
section not smaller than 2.5mm². For longer distances we recommend 4mm².

ALWAYS USE CLASS 2 WIRING FOR THE SPEAKERS CONNECTION.
Remember that the minimum load impedance for stereo or mono amplifiers is 4

. In bridged

mode the impedance must be not less than 8

. For a reliable operation under any circumstance connect

lower load impedances than just specified.

Attention: use only the indicated terminals when using the amplifiers in bridge mode.



Connect the terminal blocks securely, removing the cable cover 5÷7mm from the end.



CAUTION: The output connectors are HAZARDOUS LIVE.
Be sure to avoid leaving wires exposed. This can cause
short-circuit and risk of electric shock.