Step 3test the safety reversal system, Step 4test the protector system, Adjustment step 3 – Chamberlain 3800E User Manual

Page 19: Adjustment step 4

Advertising
background image

19

ADJUSTMENT STEP 3

Test the Safety Reversal System

TEST

With the door fully open, place a 1-1/2" (3.8 cm) board
(or a 2x4 laid flat) on the floor, centered under the
garage door.

Operate the door in the down direction. The door must
reverse on striking the obstruction. Upon successful
safety reversal test proceed to Adjustment Step 4.

ADJUST

If the door stops on the obstruction, it is not traveling far
enough in the down direction. Complete Adjustment
Steps 1 and 2 Programming the Limits and Forces.

Repeat the test.

When the door reverses on the 1-1/2" (3.8 cm) board
(or 2x4 laid flat), remove the obstruction and run the
opener through 3 or 4 complete travel cycles to test
adjustment.

If the unit continues to fail the Safety Reverse Test, call
for a trained door systems technician.

IMPORTANT SAFETY CHECK:

Test the Safety Reverse System after:

• Each adjustment of limits, or force controls.

Any repair to or adjustment of the garage door
(including springs and hardware).

Any repair to or buckling of the garage floor.

Any repair to or adjustment of the opener.

ADJUSTMENT STEP 4

Test The Protector System

®

Press the remote control push button to open the door.

Place the opener carton in the path of the door.

Press the remote control push button to close the door.
The door will not move more than an inch, and the
opener lights will flash.

The garage door opener will not close from a remote if the
indicator light in either sensor is off (alerting you to the fact
that the sensor is misaligned or obstructed).

If the opener closes the door when the safety
reversing sensor is obstructed, do not operate the
door. Call for a trained door systems technician.

1-1/2" (3.8 cm) board
(or a 2x4 laid flat)

Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the other

control may also need adjustment.

• After ANY adjustments are made, the safety reversal system

MUST be tested. Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid flat) on the floor.

Safety Reversing Sensor

Safety Reversing Sensor

Without a properly installed safety reversing sensor, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.

Advertising