Motor Brushes Inspection

1. Turn the machine off then disconnect the power source.

2. Remove the motor deck socket truss screws.

3. Remove the silencer hood assembly.

4. Remove the 4 metal motor-cap retaining clips using a standard bit screwdriver.

5. Carefully dislodge the plastic motor cap via the built in hooks on both sides of each motor brush using a standard

screwdriver. (TIP: Dislodge one side of a cap fi rst, then the other.)

6. Remove the motor brush retainers via the 2 phillips screws per brush.

7. Remove each of the brushes and inspect for excessive or uneven wear.

NOTE: A brush should be replaced if its length is less than 0.25 inches.

8. Reverse the procedure to install each brush.

9. Replace the silencer hood; make sure the switch mount is fi t into the slot in the silencer hood.

10. Secure the silencer hood with the 4 socket truss screws.

VAC-290

Advertising