Creda Advanced Control Heating Systems User Manual

Page 2

Advertising
background image

With a conventional ‘wet’
heating system, when
heating goes off,
building shell cools.

It is smarter to
maintain low level
background heat.

The building shell has
to then be warmed
again before room
feels comfortable.

The room temperature
can be raised quickly
and efficiently when
needed.

This takes time and
energy - slow response.

Economical.
Responsive.
Intelligent.

• Elements (Storage) - 650W incoloy sheathed, mineral

filled elements

• Element (Direct Acting) - cable-on-foil thin facia panel

• Thermostat (Input) - integral electronic charge limiter

Maximum core temperature 670

o

C/690

o

C at full charge

• Thermostat (Output) - integral electronic thermostat with child

lock facility

• Thermal Insulation - Carbowool 128kg/m

2

, Microtherm G

and calcium silicate

• Energy Retention Cells - high density bonded magnetite

• Protection (Storage) - automatic reset core limit thermostat and

manual over-temperature cut out

• Protection (Direct Acting) - automatic reset limit thermostat and

automatic reset over-temperature cut out

• Finish - white polyester and zinc coated steel with grey base

• Cable (Storage) - 1.6m 2.5mm

2

3 core

• Cable (Direct Acting) - 1.6m 0.75mm

2

2 core

• Supply - 230/240V AC single phase

9

Model

Height A

Width B

Depth C

Feet Position D

ER300

712mm

600mm

130mm+10mm

295mm

ER400

712mm

830mm

130mm+10mm

523mm

ER500

712mm

1060mm

130mm+10mm

751mm

Minimum clearance required

• 75mm either side of heater

• 150mm in front of the heater

• 250mm directly above the heater

4 zone pilot wire central controller

Allows 7 day programming of comfort/setback time
settings of multiple pilot wire linked heaters in up to
4 separate zones.

Ref: 75 770916

Conventional heater

Dimensions

1

2

3

1

2

3

Technical Specification

Eco-Response

+44 (0) 1733 456789 www.creda-heating.co.uk

Eco-Response
Storage radiant heaters

Advanced control
heating systems

Matching TPRIII E
Electronic panel
heaters also available
for pilot wire linked
heating systems
(See page 12-13).

Control options