Controls at a Glance

xformer: Select how the output transformer is used in the circuit.

Off: The output transformer is not used and the output is

balanced with active electronics. Very clean sound with the

largest bandwidth.
On: Inserts the output transformer in the circuit. Smooths

transients providing warmer top end and thicker low mids.
Loaded: Loads down the output transformer so it saturates

easily. Provides a warm, vintage feel. Great for controlling

cymbals and sibilance in vocals.

link: Links 2 compressors to form a stereo pair. See “Using the

Link Function” for details on connecting the units.

side chain hpf: The high-pass filter cuts out low frequen-

cies in the side chain below either 120Hz or 220Hz.

manual / auto: Control the attack and release times manually or

with one of the two auto modes: *

auto1: Great for dynamic control. Use when tracking to

control peaks or to smooth out a mix.
auto2: Attack is more open making things sound big

and present.

GR meter: This 10 segment meter shows the amount of gain

reduction being performed by the compressor at any given time.