Receiving and installation – Energenics Air Free (Old) User Manual

Page 2

Advertising
background image

2



Receiving and Installation

1. Inspect the filter inside and outside for damage.

2. Adjust the height and anchor the base plate to the floor.

3. Install the white mesh screen inside the filter housing.

4. Install the black vinyl lint bag to the bottom of the filter.

5. Duct individually from the dryers to the filter.

6. If the dryer ducts are too many or to large for the filter inlet have the

duct installer fabricate a short adapter inlet to match to the filter.

7. For Outside installations, specify the side discharge with rain hood

option from Energenics. Alternatively mount a “chinamans hat” on top
of the filter (18 inches open space from the filter to the “hat”) for
outside installation. Your local duct fabricator can fabricate the “hat”.

8. For low ceiling laundries us the Side Discharge Option for horizontal

exhaust requirements.

9. The filter can be lowered to 16 inches from ground to filter bottom from

our recommended standard of 24 inches. The lint bag will simply be
harder to empty.

10. When ducting from the filter to the outside, direct the exhaust away

from sensitive air handling equipment, even minor lint by-pass clogs
compressors.

11. Duct runs longer than 50 feet to the filter are a problem, consult

Energenics for review.







Advertising