Cleaning & maintenance, Operating the therapure – Envion TPP240 User Manual

Page 6

Advertising
background image

240

9

8

CLEANING & MAINTENANCE

Keep the Therapure

®

240 functioning properly by cleaning the permanent HEPA-type filter each

time the Clean Filter Indicator Light turns on. More frequent cleaning will be necessary if the unit

is located in an area with a high level of airborne contaminants (excessive amounts of smoke, pet

dander, etc.).

NOTE: Always make sure the Therapure

®

240 is turned off and unplugged before cleaning.

»

Vacuuming will restore performance of the permanent HEPA-type filter. However,

the filter may appear stained. This is normal and does not affect performance in any way.

»

Do not use water or any household cleaners or detergents to clean the permanent

HEPA-type filter.

»

The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum

or a slightly damp cloth.
Cleaning the permanent HEPA-type filter
1. Release the inlet grill by pressing on the locking latch (see diagram of Main Parts).

2. Remove the inlet grill from the unit as shown below.

3. Grasp the left and right frames of the permanent HEPA-type filter through the indentations on

the sides of the filter enclosure and remove the filter.

4. To clean the permanent HEPA-type filter, use the brush or crevice attachment with a vacuum

cleaner. Run the attachment along the inlet and outlet side of the filter, cleaning between the

crevices as much as possible.

Do not use water or any household cleaners or detergents to

clean the permanent HEPA-type filter.

5. Once the permanent HEPA-type filter has been cleaned and checked for any possible damage,

replace the filter back in the reverse direction described here. Plug in the unit and

hold down

Timer + Power On button for 3 seconds. The clean filter light will go off and your cleaning

maintenance is done.

Exposing the Therapure

®

240 to candle/oil/fireplace soot and smoke is not recommended

and will require more frequent cleaning.

1.

2.

3.

4.

OPERATING THE THERAPURE

®

240

Controls/Settings
Power Control
– To operate the Therapure

®

240 air purifier,press the “ON/OFF” button to turn

on the air purifier, press the button again to turn off the air purifier.
Timer Control – The Therapure

®

240 air purifier can be programmed to turn off after a preset

amount of time. Press the “TIMER” button to program the timer. Each press will add one hour up to

a total of 24 hours. Keeping the button pressed will automatically increase to 24 hours, 1 hour at a

time, after that it will turn back to off.
ION Generator – Press the ION Generator button to turn on the ions. Press it again to turn

off the ions.
Speed Control – The Therapure

®

240 has three different speeds of cleaning, LOW, MED and HI.

Press “SPEED” button to cycle the settings and select the fan speed you desire. The speed state

will be shown on the LED display.
UV Control – Press the UV/VOC control button “UV/VOC” to turn on the UV lamp to kill harmful

airborne germs and reduce harmful VOC (volatile organic compounds). Press it again to turn off the

UV and VOC.
Clean Filter Indicator Light – The Therapure

®

Clean Filter Indicator Light will turn on each time

the filter needs to be cleaned.
Reset Filter Control – Press down the “TIMER” and “ON/OFF” button for 3 seconds, the clean

filter light will flash 3 times and then the clean filter light will turn off, indicating the unit has

been reset.

LED Display

ION Button

Timer Button

Clean Filter

Indicator Light

Speed Button

Power Button

UV/VOC Button