PREPARATIONS

1.1

How to install the instrument

Panel mounting, panel cut out 67 x 138 mm (2.63 x 5.43 in),

with screw brackets (supplied by the builder).

smart guide

EK

340A

ON-OFF digital controller for electrical pizza

ovens

Version 1.00 of 12

th

May 2004

File ek340a_eng_v1.00.pdf

PT

EVERY CONTROL S.r.l.

Via Mezzaterra 6, 32036 Sedico Belluno ITALY

Phone 0039-0437-852468 • Fax 0039-0437-83648

[email protected] • www.evco.it

installation with screw brackets; moderate the clamping torque, in order not to dam-

age box and screw brackets.

2

OPERATION

2.1

How to turn the instrument ON/OFF

• press

for 2 s

During the normal operation the instrument shows the tempera-

ture the chamber probe is reading (in the display at the top), the

percentage of power supplied to the top heating group (in the

LED bar at the top) and the percentage of power supplied to the

floor heating group (in the LED bar at the bottom).

2.2

How to silence the buzzer

• press

2.3

How to activate/deactivate function Quick heat-

ing

• press

for 2 s

(1)

During this function the instrument supplies the maximum power

both to the top heating group and to the floor heating group.

The temperature the instrument deactivates the function auto-

matically is “ [working setpoint - (temperature you have set with

parameter c3)] “ .

(1)

if parameter c2 has value 0, the function will not be enabled; if parameter c2

has value 2, the function will automatically be activated every time you will turn

the instrument ON; if parameter c2 has value 3, the function will automatically

be activated every time you will turn the instrument ON or pressing

for 2 s

2.4

How to turn the chamber light ON/OFF

• press

3

WORKING SETPOINT

3.1

How to set the working setpoint

• press

• press

or

within 4 s

(2)

• press

(2)

you can set the working setpoint between the limits you have set with param-

eters rA1 and rA2.

4

PERCENTAGE OF POWER SUPPLIED TO THE HEAT-

ING GROUPS

4.1

How to set the percentage of power supplied to

the heating groups

To modify the value of the percentage of power supplied to the

ENGLISH