3 regulation of humidity, 2 generating heat – EVCO EVFTFT618N7U User Manual

Page 30

Advertising
background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

30

of

62

9.2.2 Generating heat

Generation of the heat refers to a heating element.

During a heating request, the heating element outputs will be activated, with possibility of management of a switch-on

and switch-off duty cycle, defined by parameters rH6 and rH7 in a way to limit the heating power if very powerful resistors

are used, in order to prevent overheating in the cabinet.

The evaporator fan will go continuously or in parallel to the resistors output, at the speed established for the phase in

progress.

9.3

Regulation of humidity

The regulation of the humidity in the cabinet for all phases where it is envisioned and with humidity transducer enabled, is

neutral area.

Meaning with a work set-point and a neutral area within which activations of loads set-up for humidification or

dehumidification do not take place.

When the humidity goes above the neutral area value of the dehumidification differential value, the utilities set-up for

dehumidification will be activated until the humidity returns within the neutral area value.

In the same way, when the humidity goes below the neutral area value of the humidification differential value, the utilities

set-up for humidification will be activated proportionally until the humidity returns within the neutral area value. (For

management without humidity transducer, see chapter 0).

Dehumid. differential

Dehumid. neutral

area

Humid. differential

Humid. neutral area

Humid. prop. band

D

e

h

u

m

id

if

y

.

w

it

h

f

a

n

D

e

h

u

m

id

.

W

it

h

re

fr

ig

e

ra

ti

o

n

p

la

n

t

Extraction fan

compressor

Pump-down duration (see dedicated chapter

Relay humidification

Advertising