8

COOKING CYCLE

8.1

Preliminary notes

Every cooking cycle is preceded by preheating (on condition

that Delta T cooking has not been set; the work set-point is

relative to the work set-point during the first phase of the

cooking cycle, i.e. "work set-point during the first phase of the

cooking cycle + work set-point during preheating").

During pre-heat the fan is switched-on at maximum speed.

When the temperature detected by the environment probe

reaches the work set-point, the buzzer is activated for 3 s.

The opening and closing of the door causes the passage to the

first phase of the cooking cycle.

Every cooking cycle is made up from a minimum of one to a

maximum of six phases; on conclusion of a phase, the device

passes automatically to the next.

For every phase, the device can manage the following

settings:

-

the type of cooking:

-

timed (in this case, the phase has

duration for the time set and the work

set-point is an absolute value)

-

with Delta T (only if the needle probe

is enabled, i.e. if parameter P2 is set

at 1; in this case, the phase has

duration until the temperature

detected by the needle probe reaches

the core set-point and the work set-

point is relative to the temperature

detected by the needle probe, i.e.

“temperature detected by the needle

probe + Delta T set-point)

-

core (only if the needle probe is

enabled, i.e. if the parameter P2 is set

at 1; in this case, the phase has

duration until the temperature

detected by the needle probe reaches

the core set-point and the work set-

point is an absolute value)

-

the work set-point (only if timed or core cooking

has been set)

-

the Delta T set-point (only if Delta T cooking has

been set)

- the

humidification

-

the duration of the phase (only if timed cooking

has been set)

-

the core set-point (only if Delta T or core cooking

has been set)

-

the fan speed (only if fan management has been

set in “on/off” mode with dual speed or in

modulating mode, i.e. if the parameter F0 is set at

2 or 3)

-

the duration of the vent automatic opening,

intended as an advance on the conclusion of the

phase (only if timed cooking has been set).