EVCO PM100AX9S001 User Manual

Page 2

Advertising
background image

3

PRINT TEST

3.1 Print test

If you have to execute the print test:

• switch off the power supply of the instrument

• press

• switch on the power supply of the instrument.

4

SIGNALS

4.1 Signals

5

TECHNICAL DATA

5.1 Technical data

Box: self-extinguishing grey.

Size: 96 x 96 x 90 mm (3.77 x 3.77 x 3.54 in).

Installation: panel mounting, panel cut out 92 x 92 mm (3.62 x 3.62 in), with screw

brackets (they are supplied by the builder).

Frontal protection: IP 30.

Connections: extractable terminal blocks with pitch 5 mm (0.19 in) for cables up to

2.5 mm² (0.38 sq in, serial connection RS 485, standard model) and with pitch 7.5 mm

(0.29 in) for cables up to 2.5 mm² (0.38 sq in, power supply), 8/8 RJ telephone connec-

tor (serial connection TTL, by request).

Ambient temperature: from 0 to 55 °C (32 to 131 °F, 10 ... 90% of relative humidity

without condensate).

Power supply: 110-240 Vac, 50/60 Hz (standard) or 12-36 Vac/dc, 50/60 Hz

(by request); the maximum power consumption is 12 W.

Display: instrument mode indicator.

Maximum size of the roll of paper: 58 x Ø 30 mm (2.28 x Ø 1.18 in).

Print width: 48 mm (1.88 in).

Dot number (for every line): 384.

Print density: 8 dot per mm.

Serial communication: RS 485 (standard model) or TTL (by request).

LED

on/off

MEANING

ON/OFF LED

if it is lighted, the instrument will be in the ON mode

6

ELECTRICAL CONNECTION

6.1 Electrical connection