Ntroduction and technical, Echanical, Nstallation – Flintec KPFD-8 User Manual

Page 3: Lectrical, Onnections, Igital, Able, Onnection

Advertising
background image

Junction Box Type KPFD – Technical Manual, Rev. 1.02 December 2007

Page 3 of 4

I

NTRODUCTION AND TECHNICAL

D

ATA

The Polyester junction box is designed for the parallel connection of up to 8 digital load cells.

Type

No. of load cells

Housing size

Inputs

Output

KPFD-8

up to 8 digital LC

100 x 320 x 81 mm

8x M16

1x M16

The junction box type KPFD is special designed for weigh bridges and silos including surge arrestors for
lightning protection. It can be connected to the instrumentation with a special shielded cable (3x twisted pair
cable, AWG24, and shield according DIN 47 100).

Housing material:

Polyester

Protection class:

IP66

Cable connection:

With screw terminals

Corner correction:

Not required

Other:

Over-voltage protection by surge arrestors

M

ECHANICAL

I

NSTALLATION

Look for a mounting location which is as dry as possible and protected from environmental stress.

E

LECTRICAL

C

ONNECTIONS

1

2

2

1

1

2

2

1

Figure 1: Dimensions in [mm]

The earth screw (see (2) in fig.1) has to be connected to protective earth or you must establish an electrical
connection to the weigh modules for potential equalisation.
The connection sequence of the load cells should correspond to the corners of the scale, i.e
Corner 1 = Load cell 1, Corner 2 = Load cell 2, etc.

D

IGITAL

L

OAD

C

ELL

C

ABLE

C

ONNECTION

First the cable gland (see (1) in fig.1) must be loosened. Then you have to feed the load cell cable through
the cable gland unless the shrink tube is fully disappeared in the box, because sealing and strain relief must
be done at the cable and not at the shrink tube. The wires (wh, br, ye, gn, gr, pk) have to run below the
printed circuit board and will be pulled back to the top at the upper end of the printed circuit board. Afterwards
you can connect the cables to the screw terminals as indicated below:

Cable coulour

Description

Terminal designation

white

= Excitation + (Input +)

weiss / white

brown

= Excitation – (Input –)

braun / brown

yellow

= RS485A out

gelb / yellow

green

= RS485A out

grün / green

grey

= RS485A in

grau / grey

pink

= RS485A in

rosa / pink

transparent

= Cable shield

transparent

After all conductors have been clamped to the terminals, the cable glands must be tightened. Please verify
that all cable glands are tight and the cable is fully stress relieved.