Intrepid 1640 woodburning stove – Vermont Casting 1640 User Manual

Page 11

Advertising
background image

11

Intrepid 1640 Woodburning Stove

30000830

Fig. 17 Parallel installation, vertical chimney connector, two
wall shields.

A. 36" (914mm)
B. 30" (762mm)
C. 1"

(25mm)

D. 35" (889mm)
E. 44" (1118mm)
F.

40" (1016mm)

IN

TREPI

D II

C

C

C

C

D

F

A

B

E

D

ST508a

Fig. 18 Parallel installation with rear wall pass-through, two
wall shields.

A. 36" (914mm)
B. 13" (330mm)
C. 35" (889mm)
D. 1"

(25mm)

E. 40" (1016mm)
F.

30" (762mm)

G. 44” (1118mm)

B

F

G

C

D

C

E

A

D

ST509a

Fig. 19 Corner installation, vertical chimney connector, two
wall shields.

B

B

A

D

A

C

C

A

D

A

A. 1"

(25mm)

B. 34" (864mm)
C. 48" (1219mm)
D. 35" (889mm)

ST510a

Parallel installation with rear wall pass-through,
two wall shields.
Fig. 18: Reduced clearances for
both rear and side walls. Wall shields may meet at
corner if desired. Shielding for connector is centered
behind connector. Wall pass-through must comply
with codes.

Corner installation, vertical chimney connector,
two wall shields.
Fig. 19: Reduced side clearances.
Wall shields MUST meet at corner.

Advertising