Connections to flues soot doors, Thermostat – Charnwood Country 15B User Manual

Page 8

Advertising
background image

to the pump so that if the gravity
return temperature drops below 45 C
then the pump will cut out. This will
help to prevent condensation forming
on the boiler faces and will thereby
increase the life of the boiler. It will
also ensure that priority is given to the

º

domestic hot water. These thermostats

are available from ourselves if you are
unable to obtain them locally.

There are several ways of connecting
the stove to the flue. These are
illustrated in figures 8 to 10.

If the optional vertical rear flue
connector is used then the chimney
may be swept through the appliance.

Horizontal lengths of flue must be
kept to a minimum and should not be
more than 150mm (6 inches) long.
The sealing face of the flue collar
must be coated with fire cement
before fixing to the body of the stove
using the two screws provided. The
blanking plate must be removed,
sealed with fire cement and refitted,
care being taken to ensure that the

Ensure that the

canopy is securely bolted to the body
of the stove.

It is possible to pass a 16 inch
diameter sweeps brush through the
appliance but in most back outlet
installations it will be necessary to
have a soot door to enable the
chimney to be swept. This may either
be in the actual brickwork of the
chimney or in the register plate.

CONNECTIONS TO

FLUES

SOOT DOORS

fold

on the clamping plate is in line with
the lugs on the firebox as shown in
Fig. 12. Ensure the clamping plate
does not prevent the throat plate from
seating correctly. All flue connections
must be well sealed.

Various types and positions of soot
doors are shown in figures 8 to 10.

Before lighting the fire check the cold
setting distance of the thermostat.

Remove the cover plate on the left
hand side of the stove to give access to
the thermostat. With the control knob
at the maximum setting the flap
should be 18 mm from the air inlet as
shown in Fig. 13. To adjust the
distance slacken the locking nut and
adjust as necessary. When set correctly
re-tighten the locking nut. Ensure that
the flap opens and closes freely as the

THERMOSTAT

Soot Door

In Side or Rear

Of Chimney

Register Plate

Soot Door

With Soot Door

Alternative

Positions

Soot Door

Alternative

Positions

With Bricked Up Fireplace

With Rear Flue Connection

With Top Flue Connection

Register Plate

With Soot Door

Fig 8. Vertical Register Plate

Fig 9. Horizontal Register Plate

Fig 10. Horizontal Register Plate

Register Plate

With Soot Door

Soot Door

Alternative

Positions

Connector

With Vertical Rear Flue

Fig 11. Horizontal Register Plate

Thermostat Flap

Locking Nut

Fig. 13. Thermostat Setting

18mm

Page 7

Country 15B 09/03

Blanking Plate

Blanking Plate

Clamping Plate

with fold horizontal

Back of the Stove

Clamping plate finishes

flush with inside face of

firebox top and bottom.

with fire cement

Seal Blanking Plate

Fig. 12. Flue Blanking Plate.

Advertising