Troubleshooting – Futaba RS302CD User Manual

Page 32

Advertising
background image

32

TROUBLESHOOTING

If your servo does not operate, it intermittently stops operating, or it operates

erroneously, take the action shown in the table below. If this does not correct the trouble,
please contact a Futaba dealer.

Table 0-1 Check list

Check point

Check item

Action

Battery

Dead battery.

Incorrect loading voltage.

Replace the battery.

Charge the LiPo battery.
Reload the batteries in the correct polarity.
Change the recommanded battery

Connecter

Faulty contact connection.


Dirty contacts.

If the contact pin is deformed, correct it.

Wipe with a dry cloth

Servo horn

Looseness of screws

Fasten the screws

Command

ID, baud rate, check sum

Conform the command packet rules

Cable

Short-circuit

Change the cable

Before requesting repair, read this instruction manual again and recheck your system.

Should the problem continue, request repair service as follows:

Describe the problem in as much detail as possible and send it with a detailed packing

list together with the parts that require service.

_Symptom (Including when the problem occurred)
_System(Application configuration)
_Model Numbers and Quantity
_Your Name, Address, e-mail address, and Telephone Number.

If you have any questions regarding this product, please consult your local Futaba dealer.