Cooper Lighting AMETRIX ADY071480 User Manual

Large, indoor cr, Visor and non-visor

Advertising
background image

Warning

: Before starting any work ensure

that all sources of power are turned off. All

work must meet local/national codes and be

performed by a certified electrician. Do not

mount fixtures vertically.

Installation Instructions

Vault

C-Scroll

Roundel

These installation instructions are valid with the above Ametrix styles.

1

3

2

Sheet 1 of 3

Large, INDOOR

CR

(Cantilever, Remote ballast)

Visor and Non-Visor

ADY071480 REVA(ECN080352)

Mounting cantilever to structure

J-box

(by others)

#8-32 x3/8"

Set screw

Canopy

Mounting plate

1/4" fastener

(by others)

(4x)

Wiring the fixture

Use additional bracing around
J-box to support J-box.

Exploded view and part call-out

Canopy

#8-32 x3/8"

Set screw

(2x)

Fixture head

#10-32 x1

End screw

(2x)

Yoke end cap

Yoke assembly

1/4-20 x3/4"

Hex bolts

(2x)

1. Prior to attaching fixture head to cantilever, remove both

#8-32 x3/8" set screws and allow canopy to slide down

pendant.

2. Feed power wire through wiring holes and using appropriate

fasteners, secure mounting plate to structure. Use additional

bracing around J-box to support J-box.

Attention:

All large fixtures require additional bracing/structure

around J-box to support fixture.

1. After pulling wires through wiring holes in mounting plate,

attach appropriate wires and ensure all connections are

properly matched.

2. Push connections into J-box and secure canopy using both

#8-32 x3/8" set screws.

3. Refer to supplementary sheet for instructions on aiming and

sealing the fixture.

#8-32 x 3/8"

Set screws

(2x)

Wiring holes

Canopy

Securing fixture to cantilever

1. To remove fixture head from yoke assembly, remove #10-32

x1 end screw from one side.

2. Remove the #6-32 x 1/4" Flat head screw from the inside of the

yoke arm and remove the yoke end cap.

3. With fixture head removed, secure yoke to cantilever using

1/4-20 x 3/4" hex bolts.

4. Run wiring from fixture head, into pendant and out holes in

mounting plate.

#10-32 x1

End screw

Yoke arm

end cap

Fixture head

#6-32 x1/4

Flat head screw

1/4-20 x3/4"

Hex bolts

(2x)

Advertising