Wiring Power to the Unit

Wiring Power to the Unit

The 110 VAC outlet must be dedicated to the unit ONLY. This outlet should be wired back to its own 10 Amp
minimum circuit breaker. This will prevent two problems:

• Other equipment cannot introduce spikes, noise, surges or dips into the power circuit.

• The system’s operation will not be affected if any other equipment develops a short circuit across the

power line.

Connect the transformer into a 110 VAC outlet after all connections have been made. Any other type of outlet will
cause damage to the system.