Wiring a gate operator, Page 16 – Chamberlain EL2000 User Manual

Page 18

Advertising
background image

Page 16

Wiring a Gate Operator / Key Switch / PIR / REX

Wiring a Gate Operator

Wiring a Key Switch/PIR/REX

Any auxiliary opening device such as a key switch or PIR (Passive Infrared Device), or an exit request button
(REX) that provides normally open contact closure can be hooked up to the Door Input terminals.

IO Output Board

LED 2

LED 1

RELAY 1

RELAY 2

RELAY 3

RELAY 4

J3

J5

J4

J1

NO

NC

C

NO

NC

C

NO

NC

C

NO

NC

C

LED 4

LED 3

RES

TELCO

J6

J8

Use 18-24 AWG

NOTE: The gate operator can be
connected to any of the 4 relays.

Normally Open

Common

DO NOT overload
the removable
terminal block
connectors. One
wire per hole.

Output Board

(See page 6)

IO Input Board

J2

J3

DOOR

STAT 4

EXIT

REQ 4

COM

DOOR

STAT 3

EXIT

REQ 3

COM

DOOR

STAT 4

EXIT

REQ 2

COM

DOOR

STAT 1

EXIT

REQ 1

COM

J5

J7

J6

J4

POSTAL

AUTO

J1
POWER
12VAC/DC

Use 18-24 AWG

NOTE: Additional opening or exit devices can be
connected to any of the 4 Exit Request inputs.

Exit Request

Common

Input Board

(See page 6)

NOTE: Refer to your gate operators owner’s manual for proper relay strike time.