Wiring a Door Sensing Device / AutoCall

Wiring a Door Sensing Device

The units can monitor the position of up to four doors/gates and may react to a change in their status with one of
the relays (not set as a control relay). For example, if a door is pried open or is held open after its relay deactivates,
the unit will record the breach in its transactions and can perform the following actions:

• Energize a relay to activate an alarm device such as a siren, light or CCTV camera.

• Main use is to terminate strike time early.

Wiring the AutoCall Feature

Using the AutoCall feature, the unit will automatically call the main residence phone when a driveway sensor is
activated (any device that provides a contact closure). For example, when a visitor drives over a loop sensor that
is connected to the AutoCall feature, the unit will call the main residence phone automatically so the visitor can
speak to the resident without pressing the call button on the unit.

IO Input Board

J2

J3

DOOR

STAT 4

EXIT

REQ 4

COM

DOOR

STAT 3

EXIT

REQ 3

COM

DOOR

STAT 4

EXIT

REQ 2

COM

DOOR

STAT 1

EXIT

REQ 1

COM

J5

J7

J6

J4

POSTAL

AUTO

J1
POWER
12VAC/DC

Use 18-24 AWG

Door Status

Common

Input Board

(See page 6)

NOTE: Additional sensing devices can be
connected to any of the 4 Door Stat inputs.

IO Input Board

J2

J3

J5

J6

J4

POSTAL

AUTO

J1
POWER
12VAC/DC

Loop

Detector

Use

18-24 AWG

Common

In

Loop

Sensor

Input Board

(See page 6)

NOTE: Door sensing device should provide contact closure when door is closed.