7. Unscrew the Canopy loop collar(H )from the Canopy loop.
Take the canopy and pass over the Canopy loop.
approximately one half of the canopy loop exterior threads
should be exposed. Adjust until desired height is reached. *the
Canopy loop collar should fit snugly on the Canopy loop after
the canopy is installed. Remove Canopy and Canopy lock
collar.
8. Assemble the fixture and have an assistant or secure
support hold the weight of the fixture while you complete the
wiring connections.
9.Thread the fixture wires and ground wire of the assembled
fixture through the canopy loop and nipple and into the outlet
box.

For Customer Service, contact the place of purchase to arrange for replacement parts.

CONNECTING THE WIRES (Fig 2)

10. Attach the power supply wires to the fixture lead wires by

connecting BLACK to BLACK (or SMOOTH) and WHITE to

WHITE (or RIBBED).

11. Attach the GROUND wire(GREEN or COPPER) from the

Junction Box and the fixture Ground wire to the green Ground

Screw on the Mounting Bracket (D) or connect both wires

together using the correct size of wire connectors.

NOTE: Twist the wires together in the same direction you twist

the wire connector onto the wires.

12. Tuck these wire connections neatly into the Junction Box.

Fig. 2

FINISHING THE INSTALLATION
13. Raise the Canopy (G) to the ceiling. Secure in place by
tightening the Canopy Loop Collar (H) onto the Canopy Loop
(F).
14. Install the light bulbs and glass shade according to the
fixture assembly sheet.

YOUR INSTALLATION IS NOW COMPLETE.

RETURN POWER TO THE JUNCTION BOX

AND TEST THE FIXTURE.

For Chandelier Light Fixture

INSTALLATION INSTRUCTIONS

WARNING ! SHUT OFF POWER AT FUSE OR CIRCUIT BREAKER.

Fixture Name: Candace 1260-5 /-D5/-9/-3P PW/RBZ

HANGING THE FIXTURE (Fig.1)

1. Carefully remove the new fixture from the carton and the

yellow bag that holds all parts. Check that all parts are included

as shown in the illustration and parts list.

2. Shut off the power at the circuit breaker and remove old

fixture from ceiling, including the old mounting strap.

3. Thread Nipple(C) into Canopy Loop (F) until snug.

4. Thread other end of the Nipple (C) with Canopy Loop

attached into Mounting Strap (D).

5. Place Lock Washer (B) over end of Nipple (C) protruding

through Mounting Strap (D) and thread Hex Nuts (A) onto

Nipple until tight.

6. Take this mounting strap assembly and mount to ceiling

junction box with Mounting screws (E). Tighten screw securely

with screw driver.

Fig. 1

G

CHAIN

J

H

F

E

D

JUNCTION BOX
(CEILING)

A

C

B

L