Assembly

cont.

Step 5

(cont)

Step 4

(cont)

■ Attach regulator to tank.

■ Install tank.

■ The support ring and each log is marked with a Letter which corre-
sponds to the location where logs should be placed. Each log also has
recesses that are lettered which indicate where adjoining logs are to be
placed.
Start with log “A” then “B”, etc.

Step 5

• You must provide propane gas and propane tank. Use a standard 20 lb.

propane tank only. The L.P. cylinder must have a shut-off valve terminating
in a Type 1 L.P. gas cylinder valve outlet.

• Use this fireplace only with a propane vapor withdrawal supply system.

See Chapter 5 of the Standard for Storage and Handling of Liquefied
Petroleum Gas, ANSI/NFPA 58
. Your local library or fire department will
have this book.

• A minimum supply pressure of 11.0 W.C. is required for the purpose of

input adjustment for propane gas.

• The pressure regulator and hose assembly supplied with the fireplace

must be used.

• The installation must conform with local codes, or in the absence of local

codes, with National Fuel Gas
Code, ANSI Z223.1.

• A dented, rusted or damaged

propane tank may be hazardous
and should be checked by your
tank supplier. Never use a propane
tank with a damaged valve connec-
tion.

• The propane tank must be

constructed and marked in
accordance with the specifications
for LP gas cylinders of the U.S.
Department of Transportation
(DOT).

• Never connect an unregulated

propane tank to the heater.

Leak Check

WARNING

• Perform leak test outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the fireplace until connection has been leak tested and
does not leak.

Regulator/Cylinder

Connection

• Make 2-3 oz. of leak check solu-
tion (one part liquid dishwashing
detergent and three parts water).
• Apply several drops of solution
where regulator connects to
Cylinder.
• Make sure control knob is OFF.

• Turn Cylinder Valve ON.
If bubbles appear at connection,
there is a leak.
• Turn Cylinder Valve OFF.
• If leak is at Regulator/Cylinder
Valve connection: disconnect,
reconnect, and perform another
leak check. If you continue to see
bubbles after several attempts,
cylinder valve is defective and
should be returned to cylinder’s
place of purchase.
If NO bubbles appear at connec-
tion, the connection is secure.
• Turn Cylinder Valve OFF.
NOTE: Whenever gas connection
is loosened or removed, you
must perform a leak test.

Standard 20 lb. tank

Cylinder Valve

Control Knob