5 dome abnormal phenomenon operation – IC Realtime 1.3 Megapixel 18X PTZ Network Camera with Up-to 300 ft IR (ICIPMP1808IR) User Manual

Page 32

Advertising
background image

26

IR SENSITIVITY: :04

IRLIGHT CTRL :ZOOM PRI

NEAR LIGHT :50

FAR LIGHT :50

IRLIGHT COMP: 03

BACK EXIT


z

HEATER CONTROL: It is to set temperature control mode. It includes three modes: auto/normal

open/normal close. Please use the left/right button on the keyboard or in the speed dome terminal menu
to set.

z

OPEN TEMPERATUREP: This function is on when the heater control mode is auto. It is for you to set

temperature to enable the heater.

z

CLOSE TEMPERATURE: This function is on when the heater control mode is auto. It is for you to set

temperature to disable the heater.

z

BACK: Go back to the previous menu.

z

EXIT: Log out the system menu.

4.4.5

IR Light Setting





Move the cursor to highlight IR LIGHT SETTING button and then click confirm button.
z

IR SENSITIVITY: Here you can enable the IR light sensitivity function.

z

IR LIGHT CTRL: There are three options: Zoom rate has the higher priority and manual. Please use the

left/right button to set.

z

NEAR LIGHT: It is the medium and near light brightness. This function is valid in MANUAL mode.

z

FAR LIGHT: It is the far light brightness. This function is valid in MANUAL mode.

z

IR LIGHT COMPENSATION: It is the whole compensation level of the IR light. This function is valid

when the zoom rate has the higher priority.

z

BACK: Go back to the previous menu.

z

EXIT: Log out the system menu.

4.5 Dome Abnormal Phenomenon Operation

4.5.1 Restore to Factory Default Setup

From main menu-> SYSTEM INFORMATION, move cursor to FACTORY DEFAULT and click confirm button.
Dome will reboot and all the setups restore to factory default setup.

4.5.2 PTZ Movement is not smooth

From menu to SYSTEM INFORMATION, move cursor to RESTART and click confirm button. This reboot
will not modify all activated setup (such as preset, tour and pattern)


Advertising