Quick Guide

14

Input/output box connections

Terminal strips

Earth ground. To ground.
RS-485 A/B. To and from a DVR or
additional keypad. Observe polarity.
(Optional, use if you do not use the RJ45
connection.) You can use both the wire
terminals and the RJ45 connection for
RS-485.
RS-422 IN A/B. In from an upstream
Digiplex device such as an RS-422
keypad, alarm chassis. ASCII converter,
or time/date generator. Observe
polarity.

RS-422 OUT A/B. Out to downstream
matrix switchers and PTZ cameras; can
also connect to Digiplex controllers or
ASCII converters. Observe polarity.
Speaker shield, speaker. To speaker, if
used (KTD-405A only).

Power cable

For safety, use a tie-wrap to secure the
power cable to the tie-in.

Bias switch

Use to load the RS-485 line appropriately.
Slide the switch up for the ON position.

CAUTION: Unless the system

includes a bridge connection
using fiber or Ethernet, turn on
the bias switch for only one
keypad per system.

CAUTION: Earth ground. For surge

protection you can connect to
ground at every I/O box.
RS-485 shield. Ground at only
one end of each continuous
segment of shield.