Specifications, Sentrol – Interlogix 6250FM Series User Manual

Page 4

Advertising
background image

NOTE: This unit will fit in most standard single gang electrical boxes or
rough-in plates, available at any electrical supply store.

SPECIFICATIONS

FEATURES
Pulse Count ......................... Bi-directional, 1 zone (2 pulses)

with Motion Verification

Capture Zone (at 70½ F)

Wide Angle (90½) ................... 30' (9.14m) x 30' (9.14m)
Single Spot ...................................... 40' (12.19m) range
Vertical Barrier ................................. 40' (12.19m) range
Pet Alley (90½) ................................... 30' (9.14m) range
360°Ceiling ...... 15' x 20' (4.57m x 6.10m) at 8' (2.44cm)

mounting height

....... 16' x 30' (4.88m x 9.14m) at 12' (3.65m)

mounting height

.... Ceiling mounting height up to 12' (3.65m)

Mounting ............................................ Wall, corner, or ceiling
LED indicator ............................................................ Walktest
Size ...................................................... 2.75" (6.99cm) Width

4.50" (11.43cm) Height

1.63" (4.13cm) Total Depth

1.37" (3.49cm) Depth behind wall

0.25" (0.64cm) Depth in front of wall

Color .................................................................. White/White

ELECTRICAL
Voltage ............................................................... 7 to 16 VDC
Current ............................................ 8 mA typical, 10mA max.
Maximum relay rating ..................................... 16VDC, 50 mA
Alarm output ............. Fail safe contacts w/ 10 ohms in series,

6255FM - Form A, Normally Closed (NC)

6257FM - Form C, Normally Closed and Open (SPDT)

Alarm duration ................................................ 2 to 5 seconds
Cover tamper contacts ................................ Normally Closed,

rating: 50 mA, 12VDC

(6257FM only)

ENVIRONMENTAL
Operating Temperature ........... 0°F to 120°F (-17°C to +50°C)
Humidity ................................... 10% to 90% noncondensing
RFI immunity ...... greater than 10V/meter from 0 to 1000MHz

Side View

2.75"

6.99 cm

4.50"

11.43 cm

®

Front View

ORDERING INFORMATION

PART

LOOP

ELECTRICAL

COMMENTS

LISTING

NUMBER

TYPE

CONFIGURATION

6255FM

Normally Closed

N.C. – Form A

No Tamper

UL

6257FM

Normally Closed or Open

SPDT (N.C. and N.O.) – Form C

Incl. Tamper

UL

12345 SW Leveton Dr.

Tualatin, OR 97062

Tel.: 503.692.4052 Fax: 503.691.7566

U.S. & Canada: 800.547.2556
Technical Service: 800.648.7424
FaxBack: 800.483.2495

CORPORATE HEADQUARTERS

Sentrol reserves the right

to change specifications

without notice.

© 2000 Sentrol

SENTROL

13048 Rev. B 06/00

Static/lightning immunity ............. 2.5KV, 2 joules max energy

impulse, 1 msec rise / 50 msec decay

4.5"

11.43 cm

1.63"

4.13 cm

.25"

0.64 cm

1.37"

3.49 cm

Advertising