Tamper (cover/external contact)

If a tamper condition does not restore:

Make sure the cover tamper spring is properly installed.
The tamper spring must be properly seated into the switch
post groove.

Figure 9. Tamper spring

Switch post groove for proper

tamper spring installation

Make sure the proper value end-of-line (EOL) resistor is
installed (4700 ohms series resistor).

4

319.5 Crystal MaxLife Door/Window Sensor Installation Instructions

Figure 10. External contact wiring

Door/Window

Contacts

EOL resistor

Sensor

4.7 Kohm

Make sure the EOL resistor is properly seated in the
terminal block.

Make sure the terminal block contacts are securely
fastened.

Make sure the external contact wiring meets required
specification.

Open (reed switch/external contact)

If an open condition does not restore:

Make sure the input selection jumper is in the correct
position.

Make sure the arrow on the magnet and the guide line on
the transmitter are aligned and within 3/8 in. (0.95 cm) of
each other.

Verify that the external contact is operating properly in all
conditions of operation.

Specifications

Model number

Brown: 60-362N-11-319.5 (NX-651N)
White: 60-362N-10-319.5 (NX-650N)

Frequency 319.5

MHz

Compatibility

Interlogix 319.5 MHz control panels/receivers

Battery type

3.0 V, 1300 mAh lithium

Required batteries

Duracell DL 123A, Energizer EL123, Sanyo
CR123A

Estimated battery life

5 to 10 years at 20°C (68°F) depending on
the number of activations per day

Magnet gap

3/8 in. (max.)

Supervisory interval

64 minutes

End-of-line resistor

4.7 Kohm

Typical RF output
power

0.25mW EIRP

Operating temperature

32 to 120°F (0 to 49°C)

Storage temperature

-30 to 140°F (-34 to 60°C)

Relative humidity

0 to 85% noncondensing

Dimensions (LxWxD)

3.02 x 1.5 x 1.02in. (81 x 38 x 26 mm)

Weight

44 g

Listings

UL 1023, UL 634

Replacement plastics
600-1063-60-362N-10


600-1063-60-362N-11


D/W sensor 60-362N-10 - 319..5
replacement enclosure, 5 pack, white

D/W sensor 60-362N-11 - 319..5
replacement enclosure, 5 pack, brown

Regulatory information

Manufacturer

UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA

FCC compliance

This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.

FCC ID: B4Z-914D-DWS