Installation

To install the camera:

1. Fasten the camera to a wall or ceiling (or another

solid surface). The camera must be stable when
connected.

2. Connect the 75 Ω coaxial cable to the video

output.

3. Connect the power cable to the camera.
4. Adjust the camera position and angle as

required.

Specifications

Power supply

12 VDC ± 10% / 500mA

Current

50 mA

Power consumption

0.6 W max.

Operating temperature

-10 to +50 °C (14 to 122°F)

Storage temperature

-20 to  70 °C (-4 to +158°F)

Weight

320 g (0.7 lb.)

Dimensions (H ×Ø)

60 x 100 mm (2.36 x 3.94 in.)