Quick Start Guide

7 EN

Connecting the devices

See Figure

(Connections on the base of the camera).

1. Ethernet RJ45 PoE port

Connect to network devices.

2. Video

output

Connect to a CCTV monitor.

3. Audio

output

Connect to an audio output.
Line level, 600 Ω.

4. Audio

input

Connect to an audio input.
2.0 to 2.4 Vp-p, 1 kΩ.

5. Power

LED

Illuminated when power is connected.

6. Power

supply

Connect +12 VDC power supply.

7. RS-485

D+,

D-

Connect to an RS-485 device such as a PTZ dome camera.

8. Alarm outputs

Connect 1A/1B and 2A/2B to alarm output devices.

9. Alarm

inputs

Connect IN1/GND and IN2/GND to alarm input devices.

10. Ground

Connect to ground.

Accessing the SDHC card

Insert an SDHC card up to 32GB for local storage in the camera (see
Figure

, item

). The card is not supplied with the camera.

Video and log files stored on the SDHC card can only be accessed via
the Web browser. You cannot access the card using TruVision
Navigator or a recording device.