12 T

ROUBLESHOOTING

P

RESARIO

N

OTEBOOK

M

AINTENANCE

AND

S

ERVICE

G

UIDE

1200XL S

ERIES

Presario 1200 Series

Models: XL101-XL113, XL115, XL118-XL127

Diskette Drive Test Error Codes

Error Code

Description

Recommended Action

600-xx

Diskette ID drive types test

failed

1. Replace the diskette media and

retest.

2. Check and/or replace the diskette

power and signal cables and retest.

3. Replace the diskette and retest.
4. Replace the system board and retest.

601-xx

Diskette format failed

602-xx

Diskette read test failed

603-xx

Diskette write, read, compare

test failed

604-xx

Diskette random read test failed

605-xx

Diskette ID media failed

606-xx

Diskette speed test failed

609-xx

Diskette reset controller test

failed

610-xx

Diskette change line test

697-xx

Diskette type error

698-xx

Diskette drive speed not within

limits

699-xx

Diskette drive/media ID error

1. Replace media.
2. Run the Configuration and Diagnostics

Utilities.

Serial Test Error Codes

Error Code

Description

Recommended Action

1101-xx

Serial port test failed

1. Check port configuration.
2. Replace the system board and retest.