Dutchwest natural vent gas heater, Venting system assembly – CFM Corporation 2467 User Manual

Page 9

Advertising
background image

9

Dutchwest Natural Vent Gas Heater

30002008

Snapstat

Left Air Duct

ST671

Fig. 12 Install the snapstat and connect the extension wire
terminals. View is with top removed, however, access is
available through the rear when installing fan before gas line
connection.

9. After sliding the firebox in place, the rheostat control

switch attaches to the left side of the valve bracket
at the front of the stove. (Fig. 13)

Remove the plug from the rheostat bracket.

Insert the switch box shaft through the hole in
the back of the right side of the valve bracket,
aligning the locator pin with the smaller hole in
that bracket.

Attach the control knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat
wire harnesses together.

10.Plug the power cord into a standard grounded 110

volt household outlet. If the fan control knob is not
turned to the OFF position, the fan will turn on when
the temperature at the snapstat reaches
approximately 109

°

F.

MOTOR

SNAPSTAT

ON/OFF

RHEOSTAT

WHT

WHT

BLK

BLK

BLK

GRN

BLK

POWER

ST196

Fig. 14 #2767 / FK26 fan wiring diagram.

Retaining Nut

Control Knob

ST758

Fig. 13 Attach rheostat to left side of valve.

Rheostat

Venting System Assembly

The venting collar is on the sheet metal draft hood/heat
exchanger assembly, over the firebox. Use a B-vent
adapter, from the same maker as the rest of the B-vent
components, to join the first section of venting to the
draft hood.

The stove includes a spill switch. Operating this stove
when not connected to a properly installed and main-
tained venting system, or tampering with or disconnect-
ing the spill switch, can result in carbon monoxide (CO)
poisoning and possible death.

The stove includes a bracket for installing decorative 6”
(150mm) round stove pipe around the B-vent, for
appearance purposes only. The decorative pipe need
not be concentric with the vent pipe.

If the installation includes decorative stove pipe around
the venting system, make a cardboard template of the
decorative pipe by tracing its circumference. Put this
template in the flue recess in the stove top. Position
the template to fit well against the front of the recess.
(Fig. 16) Use this template to locate the bracket to hold
the decorative pipe. Depending on spacing, the bracket
may fit inside the decorative pipe without interfering
with the vent system. Fasten the bracket to the draft
hood/heat exchanger assembly with a sheet metal
screw.

Template

Sheet Metal Screw

Bracket

ST777

Fig. 16 Use a template to locate the bracket for decorative
pipe to surround the B-vent pipe.

Insert the B-vent adapter into the flue collar and drill
1/8” (3mm) pilot holes through both the stove’s collar
and the adapter. Attach the adapter to the flue collar
with sheet metal screws. (Fig. 17)

ST778

Fig. 17 Attach the B-vent adapter to the flue.

Advertising