Fitting the integrated appliance door

Where non-standard integrated appliance doors are supplied, additional fitting
instructions are required to ensure compatibility with this product.

The machine is supplied with a fitting template and these instructions should be
followed as normal.

However, the fitting template needs to be located lower down the fascia door;
this is shown below.

The amount of offset, Y, depends on the height of the fascia door and can be
calculated as X = 723mm.

For example, if you have a 731mm tall fascia door and are fitting a door to your
dishwasher, then Y = 731-723 = 8mm.

Fitting template

Y off

set

X Door height

Ensure that the hinge tensioners are adjusted to balance the weight of the door.