Installation/Venting

This appliance is fully compatible with any 600mm deep kitchen units and
complies with stringent EEC regulations.

Your dryer is supplied with a vent hose which will extend to approximately
2.4 m. We strongly recommend that this is vented through the wall with the
attachment provided.

The position of the hole (100mm diameter) for the vent directly behind the
tumble dryer is shown in fig.3.

If the vent through the wall is to be positioned anywhere other than behind the dryer, the vent hose should be positioned at
floor level and through an adjacent side panel to an appropriate position.

The plinth in front of the dryer must be cut out to accommodate the air vent grill located at the bottom front of the tumble
dyer as shown in fig. 4.

PLEASE NOTE: The air vent at the front of the appliance must never be covered or blocked in any way as this will impair the
functioning of the appliance and could cause it to overheat.

Fitting the décor door

The hinges can be fastened through predrilled holes on either the left or
right hand side with the door stops being fastened to the other side.

fig. 3