Installation – Desa Tech CSPBNT EN User Manual

Page 10

Advertising
background image

www.desatech.com

111487-01D

10

For propane/LP units, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down as

shown in Figure 7. Pointing the vent down protects

it from freezing rain or sleet.

CAUTION: For propane/LP

units, use only new, black iron

or steel pipe. Internally-tinned

copper tubing may be used in

certain areas. Check your local

codes. Use pipe of 1/2" diameter

or greater to allow proper gas

volume to heater. If pipe is too

small, undue loss of volume

will occur.

Installation must include an equipment shutoff

valve, union and plugged 1/8" NPT tap. Locate

NPT tap within reach for test gauge hook up. NPT

tap must be upstream from heater (see Figure 8).
IMPORTANT:

Install equipment shutoff valve in an

accessible location. The equipment shutoff valve is for

turning on or shutting off the gas to the appliance.
Check your building codes for any special re-

quirements for locating equipment shutoff valve

to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

INSTALLATION

Continued

Figure 6 - Gas Regulator Location and

Gas Line Access Into Stove Cabinet

Back
Stove
Panel

Front
of
Stove
Unit

Gas Inlet
Connection
Access

Product
Identification
Label

Gas Log
Heater

Back View

Side View

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment trap in

supply line as shown in Figure 8. Locate sediment

trap where it is within reach for cleaning. Install

in piping system between fuel supply and heater.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into

heater controls. If sediment trap is not installed or

is installed wrong, heater may not run properly.

CAUTION: Avoid damage to

regulator. Hold gas regulator

with wrench when connecting it

to gas piping and/or fittings.

Figure 8 - Gas Connection

3"
Minimum

Sediment Trap

Gas
Regulator
(Propane/LP)

From
External
Regulator
(11"
W.C.** to
14" W.C.
Pressure)

CSA Design-
Certified Equipment
Shutoff Valve With
1/8" NPT Tap*

Approved
Flexible Gas
Hose (if allowed
by local codes)

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories

, page 19.

** Minimum inlet pressure for purpose of input

adjustment.

Tee Pipe

Cap

Joint Nipple

Figure 7 - External Regulator For

Propane/LP Gas With Vent Pointing Down

Propane/LP
Supply Tank

Vent
Pointing
Down

External
Regulator

Advertising