ELECTRICAL SPECFICATIONS

* Export 220 Volts, 2.40 KW

OPERATING ENVIRONMENTAL TEMPERATURE:

Do not store unit in temperatures of 32° F or below with tank filled with water. Make sure tank is drained and lines purged to avoid damage.

NOTE: The appliance is not suitable for unsupervised use by young children or aged or infirm persons, according to national standards.

If the main power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order

to avoid a hazard.

UNPACKING AND ASSEMBLY:

The machine is shipped with a set (4) adjustable leveling feet already mounted, (1) brew funnel, (1) brew-thru cover, and (1) water inlet fitting and

(1) Operating and Service Manual.

WATER INLET CONNECTION:

HIGHLY RECOMMENDED: A water shut-off valve and a water filter, preferably a combination charcoal/ phosphate filter, to remove odors and

inhibit lime and scale build up in the machine.

Note: In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the equipment and in order not

to void the warranty.


The tea dispenser is equipped with a ¼" flare water inlet fitting which is located in the back of the unit.

Connect the ¼" dia. Copper waterline to the ¼" flare water inlet fitting of the valve.

This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes having jurisdiction.
In addition:

1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for

cleaning underneath.

2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.
3. For use of machine outside the United States of America, connection to water supply mains should comply with the national “Model Water

Byelaws”.

The brewer must be connected to a cold water supply with an operating pressure of 20psi minimum and 90psi maximum from a ½ in. supply line.
If pressure should exceed 90psi, install a pressure regulator to reduce the operating pressure to 50psi. Use ¼ inch copper tubing for installation of

less then 25 ft. and 3/8 copper tubing for more then 25ft from a ½ in cold water supply line.

Install the water inlet fitting provided onto the inlet valve located in the back of the unit. Do not over tighten.

Connect the ¼” copper waterline to the ¼" flare water inlet fitting on the valve.

NOT RECOMMENDED! The uses of a saddle valve to hook up the brewer since most of them restrict the water flow causing inconsistent brew

batches.

MODEL NO.

VOLTS

PHASE HZ

WATTS

KW

NO. OF

HEATERS AMPS

RECEPTACLE

NEMA NO.

POWER CORD

CIRCUIT

BREAKER AMPS

FTC-3-N, FTC-3.5-N

FTC-5-N,

120

1

60

1.75

1

15

5-15R

5-15P [2 WIRES+GND]

15A

FTC-5-N, FTC-10-N

240

1

60

2.80

1

12.5

6-20R

6-20P [2 WIRES+GND]

20A

FTC-10-N

240

1

60

5.60

2

25

6-30R

6-30P [2WIRES+GND]

30A