The PROAMP-7X400 connects to PC via Ethernet:

1. Enter the IP address, IP mask and default router of the PROAMP-7X400 via

Crestron Toolbox (Functions | Ethernet Addressing); otherwise enable
DHCP.

2. Confirm Ethernet connection between PROAMP-7X400 and PC. If

connecting through a hub or router, use CAT5 straight through cables with
8-pin RJ-45 connectors. Alternatively, use a CAT5 crossover cable to
connect the two LAN ports directly without using a hub or router.

3. Use the Address Book in Crestron Toolbox to create an entry for the

PROAMP-7X400 with the PROAMP-7X400’s TCP/IP communication
parameters.

4. Display the “System Info” window (click the

icon) and select the

PROAMP-7X400 entry.

Programs and Firmware

Program or firmware files may be distributed from programmers to installers or from
Crestron to dealers. Firmware upgrades are available from the Crestron website as
new features are developed after product releases. One has the option to upload
programs via the programming software or to upload and upgrade via the Crestron
Toolbox. For details on uploading and upgrading, refer to the SIMPL Windows help
file or the Crestron Toolbox help file.

SIMPL Windows

If a SIMPL Windows program is provided, it can be uploaded to the control system
using SIMPL Windows or Crestron Toolbox.

Firmware

Check the Crestron website to find the latest firmware. (New users may be required
to register to obtain access to certain areas of the site, including the FTP site.)

Upgrade PROAMP-7X400 firmware via Crestron Toolbox.

1. Establish communication with the PROAMP-7X400 and display the

“System Info” window.

2. Select Functions | Firmware… to upgrade the PROAMP-7X400 firmware.

Program Checks

Actions that can be performed on the PROAMP-7X400 vary depending on whether
it is connected via Cresnet or Ethernet.

Cresnet Connections

For Cresnet connections, using Crestron Toolbox, display the network device tree
(Tools | Network Device Tree) to show all network devices connected to the control
system. Right-click on the PROAMP-7X400 to display actions that can be performed
on the PROAMP-7X400.

Ethernet Connections

For Ethernet connections, using Crestron Toolbox, display the “System Info window

(click the

icon) and select the Functions menu to display actions that can be

performed on the PROAMP-7X400.

Be sure to use Crestron Toolbox to create the PROAMP-7X400 IP table.

1. Select Functions | IP Table Setup.

2. Add, modify or delete entries in the IP table. The PROAMP-7X400 can

have only one IP table entry.

3. A defined IP table can be saved to a file or sent to the device.