Operating tips, Using the pm125/pm420, Servicing instructions – Carver pm420 User Manual

Page 14: Stereo /mono switch, Level defeat jumpers, Input sensitivity modification, Input polarity, Clipping eliminator activation, Figure 8

Advertising
background image

C37

P3

P4

14

J14

P5

P6

2 1

RP2

J15

J16

RP1

J1

U5

U4

ADD THIS JUMPER TO

ACTIVATE THE CH2

CLIPPING ELIMINATOR

STEREO/MONO

SWITCH

CH2 LEVEL

BYPASS

CH1 LEVEL

BYPASS

ADD THIS JUMPER TO

ACTIVATE THE CH1

CLIPPING ELIMINATOR

Servicing Instructions

CAUTION: To reduce the risk of electric shock, do not perform any servicing other than that contained in the
Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

Stereo /Mono Switch

The Stereo / Mono Switch is located on the amplifier’s main circuit board (see Figure 8) and accessible from the back
panel. Leave the switch centered for normal stereo operation, move it to the left for Bridged Mono operation, and
move it to the right for Dual Mono operation.

Level Defeat Jumpers

The Level controls can be bypassed by moving the jumpers for CH1 and CH2 (J15 and J16), which are located on
the amplifier’s main circuit board near the level adjustment pots (see Figure 8). This will lock the amplifier into full

gain (as if the Level pots were fully clockwise).

Input Sensitivity Modification

The input sensitivity of the amplifier is set at the factory to 1.5V

RMS

for rated output. To increase the sensitivity by

6dB to 0.775V

RMS

, install jumpers JP1 (CH1) and JP11 (CH2). Sockets for these jumpers are located on the

amplifier’s main circuit board (see Figure 9).

Input Polarity

The XLR input connectors on the pm125

/

pm420 are shipped from the factory with pin 2 hot (+), as indicated on the rear

panel. The polarity of the balanced inputs can be reversed by changing four jumpers located on the amplifier’s main circuit
board. Crosswire JP3 and JP4 to change the input polarity of CH1 and crosswire JP101 and JP102 to change CH2 (see
Figure 8).

Clipping Eliminator Activation

The clipping eliminator circuit can be activated by installing jumpers in sockets JP9 (CH1) and JP6 (CH2) (see Figure 8).

Figure 8

Operating Tips

Using the pm125 / pm420

Once the amplifier has been installed and wired into the system, you are ready to use it. Here are
some tips to help you get the most from it.

• Verify that the Stereo/ Mono switch has been set to the mode that you want.

• When you power the system up for the first time (out of the carton), it’s a good idea to start

with all of the amplifier level controls turned down, then advance them slowly, one at a
time, so that you can confirm that each amplifier channel is operating normally.

• Be sure that the Input Level controls are set sufficiently high to allow the preceding device

to drive the amplifier to full output. For most installations, this is wide open (fully
clockwise).

• Once you have established settings, it is a good idea to mark them down, either on paper,

or on pieces of tape or sticky-dots attached to the amplifier’s panel.

• In bi-amplified (multi-amp) systems, it is a good idea to start with the low-frequency

amplifiers turned off or down, and to check each frequency range from highest to lowest
to ensure that each loudspeaker component is operating correctly.

16

17

17

Advertising