Setup instructions, Save these instructions, Important – Intex CS7111 Krystal Clear Saltwater System 2013 User Manual

Page 13: Saltwater system/filter pump

Advertising
background image

(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 07/31/2012

189

PO

SAVE THESE INSTRUCTIONS

Page 13

English

SETUP

INSTRUCTIONS

SALTWATER SYSTEM/FILTER PUMP

Saltwater System/Filter Pump

1. Remove the Saltwater System/Filter Pump and hoses from the packaging.

2. Place the Saltwater System/Filter Pump in a location for hose (8) connections to

the plunger valve assemblies.

NOTE: Some regional regulations may require the filter pump to be

mounted on a stationary platform. There are two mounting holes located in

the pump base for this reason. Consult your local authorities for filter

pump mounting requirements.

3. Grasp the two pump hoses (8) and connect the hose nuts to the Saltwater

System/Filter Pump.

4. In a counter-clockwise motion unscrew the threaded filter housing collar (3) from

the filter housing. Place it in a safe place.

5. The Saltwater System/Filter Pump is an airtight system. In a counter-clockwise

motion turn both air release valves

(1 & 7) 1 - 2 turns to open. DO NOT remove

air release valves as water will expel with force if the motor is turned on

and injury may occur.

6. Grasp and remove the filter housing cover (4). Check to see if a cartridge is

inside the housing. If yes, replace the cover, finger tighten the housing collar

(3)

back onto the filter housing.

7. Gently finger tighten the sediment release valve located at the bottom of the

housing to be sure that water does not leak out.

8. When the pool is filled connect the hose from the electrolytic cell outlet to the

highest strainer assembly. You will find the hose connection at the bottom of the

plunger valve assembly. Use the hose nut to attach the hose.

9. Connect the second hose to the middle of the motor housing and to the

remaining liner connection.

IMPORTANT

To prevent air lock, open the lower plunger valve (connected inlet hose)

first and then the upper plunger valve (connected outlet hose). Open air

release valves, lift and lower the inlet hose until water starts to flow out of

the air release valves, close air release valves.

Advertising