Save these instructions, Warning, Important – Intex 635T Krystal Clear 2014 User Manual

Page 9: Operating instructions

Advertising
background image

(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013

107

SAVE THESE INSTRUCTIONS

English

Page 9

1. Make sure the filter pump is switched off. The switch is located on the motor housing.
2. Connect the power cord to a GFCI protected electrical outlet.

3. Turn both plunger valve handles fully counter-clockwise until they stop. This opens the

valve, allowing water to flow into the filter pump.

4. With water flowing into filter pump, the water pressure will allow the air trapped inside to

escape from the air release valve (2). When all the air has escaped water will flow out of

the

valve

(2). When this occurs gently finger tighten the valve (2) in a clockwise direction.

NOTE: The plunger valve is equipped with a vacuum release valve that will

automatically activate to minimize the suction at the pool outlet if the outlet is blocked.

This is an additional safety feature to prevent suction entrapment. The vacuum release

valve will reset once the blockage is removed and the pump is switched off. To restart

the system the air must be removed from the filter pump per previous step.

5. To operate the filter pump on “TIMER” mode:

A. Set the timer dial to the desired operating hours. See operation time table.

See Fig. 10

B. Turn on the pump by pressing the switch to “ ” position, the filter pump is now

filtering the water and will stop after the operating hours are completed. The built-in

timer will now operate for the number of hours selected at the same time each day.

C. Operating hours can be re-adjusted if necessary. Follow step A – B.

To operate the filter pump manually (without the “TIMER” mode):

A. Turn on the pump by pressing the switch to “-” position, the filter pump is now filtering

the

water.

B. To turn off the pump, press the switch to “O” position.

OPERATING INSTRUCTIONS

Risk of electric shock. Connect this product only to a grounding type receptacle
protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician
if you cannot verify that the receptacle is protected by a GFCI.

WARNING

To prevent air lock, open the lower plunger valve (connected inlet hose) first and
then the upper plunger valve (connected outlet hose). Open the air release valve,
wait until water starts to flow out of the air release valve, close air release valve.