Save these instructions, Motor pre-filter cleaning and maintenance – Intex SF60110 2014 User Manual

Page 19

Advertising
background image

195

PO

SAVE THESE INSTRUCTIONS

(195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013

English

Page 19

MOTOR PRE-FILTER CLEANING AND MAINTENANCE

1. Make sure the filter pump is switched off, then disconnect the power cord from

the electrical outlet.

2. Turn both plunger valve handles fully clockwise until they stop. This closes the valve,

prevents the water from flowing out of the pool.

3. Release the pressure first by opening the sediment
release

valve

(19) located on the lower side of the

pre-filter

housing

(see drawing 32).

4. In a counter-clockwise motion unscrew the leaf trap
cover (14), then remove the basket (16) and leaf trap
o-ring

(15) from the pre-filter housing (see drawing 33).

5. Empty and flush the basket using a garden hose, may use a plastic brush to remove

deposits from the basket. Do not use metal brush.

6. Clean and rinse the inside of the pre-filter housing and the leaf trap O-ring with

a garden hose.

7. Reinstall the leaf trap O-ring, basket and leaf trap cover to the pre-filter housing.
8. Close the sediment release valve (19) back.

1

2

32

33

19

14

15

16

35

Advertising
This manual is related to the following products: