Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

1 . Switch in OFF position
2 . No electrical power at wall outlet
3 . Compressor has reached automatic

shutoff pressure

4 . Motor overloaded

5 . Pressure switch bad

1 . Defective check valve
2 . Defective unloader valve (on pressure

s w i t c h )

3 . Low voltage
4 . Loose electrical connections
5 . Wrong gauge wire or length of

extension cord

6 . Defective motor capacitor
7 . Shorted or open motor winding

1 . Incorrect fuse size, circuit overloaded

2 . Wrong gauge wire or length of

extension cord

3 . Defective check valve
4 . Defective unloader valve (on pressure

s w i t c h )

5 . Defective motor capacitor
6 . Motor shorted or seized

1 . Low voltage
2 . Wrong gauge wire or length of

extension cord

3 . Clogged intake filter
4 . Lack of proper ventilation/room

temperature too high

5 . Defective check valve
6 . Defective unloader valve (on pressure

s w i t c h )

7 . Compressor valves failed

1 . Loose mounting bolts
2 . Tank not level
3 . Cylinder or piston is worn/scored

1 . Loose drain valve
2 . Check valve leaking
3 . Loose connections at fittings, tubing,

e t c .

4 . Tank leaks

1 . Excessive air usage, compressor too

s m a l l

2. Clogged intake filter
3 . Loose connections at fittings, tubing,

e t c .

1 . Make sure compressor is plugged in and switch is ON.
2 . Check circuit breaker or fuse at electrical panel.
3 . Release air from tank until compressor restarts

a u t o m a t i c a l l y .

4 . Allow compressor to cool for approximately 30

minutes. To reset, turn pressure switch to OFF, then
AUTO. Make sure compressor is run in a clean, well-
ventilated area.

5 . Replace pressure switch.

1 . Repair or replace.
2 . Repair or replace.

3 . Check voltage at wall outlet with voltmeter.
4 . Check all electrical connections.
5 . Check extension cord chart for proper extension cord

u s a g e .

6 . Replace capacitor.
7 . Replace motor assembly.

Do not disassemble check valve
with air in tank; bleed tank

1 . Check for proper fuse. Use time delay fuse.

Disconnect other electrical appliances from circuit or
operate compressor on its own branch circuit.

2 . Check extension cord chart for proper extension cord

u s a g e .

3 . Repair or replace.
4 . Repair or replace.

5 . Replace capacitor.
6 . Replace motor assembly.

Do not disassemble check valve
with air in tank; bleed tank

1 . Check voltage at wall outlet with voltmeter.
2 . Check extension cord chart for proper extension cord

u s a g e .

3 . Clean or replace filter.
4 . Move compressor to well-ventilated area.

5 . Repair or replace.
6 . Repair or replace.

7 . Replace valve assembly.

Do not disassemble check valve
with air in tank; bleed tank

1 . Tighten bolts.
2. Use sturdy wedge/object to bring tank to level position.
3 . Replace or repair as necessary.

1 . T i g h t e n .
2 . Remove check valve. Clean or replace.
3 . Check all connections with soap and water solution.

If a leak is detected, (1) tighten or (2) remove fitting
and apply pipe tape to threads and reassemble.

4 . Check tank for leaks with soap and water solution. If

leak is detected, tank must be replaced with genuine
replacement part.

Do not disassemble check valve
with air in tank; bleed tank

1 . Decrease usage or purchase unit with higher air

delivery (SCFM).

2 . Clean or replace.
3 . Check all connections with soap and water solution.

If a leak is detected, (1) tighten or (2) remove fitting
and apply pipe tape to threads and reassemble.

Compressor will not run

Motor hums but cannot
run or runs slowly

Flow blows/circuit
breaker trips repeatedly

Thermal overload
protector cuts out
r e p e a t e d l y

Knocks, rattles, and/or
excessive vibration

Tank pressure drops
when compressor shuts
o f f

Compressor runs
continuously and air
output is lower than
normal/low discharge
p r e s s u r e

Oil-Lubricated Compre s s o r s

w w w . c h p o w e r . c o m