Troubleshooting guide, Maintenance, Trouble- shooting guide – Cobra Electronics PI2000 User Manual

Page 11

Advertising
background image

Problem /Symptom Possible Causes Solution

Low output voltage

Using average

Use true RMS

on voltmeter

reading

meter reading

(96 VAC to 104 VAC)

Low output voltage

Overload

Reduce the

and current indicator

load

in red zone

No output voltage

Low input

Recharge

and voltage voltage

battery,

indicator in

check

lower red zone

connections
and cable

No output voltage,

Inverter switched

Turn inverter

no voltage

Off, no power to

on, check

indication

inverter,

wiring to

fuse open

inverter.
Have qualified
service
technician
check and
replace

Reverse DC

Observe

polarity correct

polarity

No output voltage

High input voltage

Make sure the

voltage indicator in

inverter is

upper red zone

connected to
12 V battery,
check regulation
of charging
system.

16

Trouble-
shooting
Guide

Troubleshooting Guide

17

Problem /Symptom Possible Causes Solution

Low battery alarm on

Poor DC wiring,

Use proper cable

all the time,

poor battery

make solid

voltage Indicator

condition

connections,

below 11 V

use new battery

No output voltage

Thermal shutdown

if load in excess of
2000W or 17.4 amperes

Maintenance

Maintenance

Allow inverter to
cool off

Reduce load, con-
tinuous operation
input current
required

Improve ventila-
tion; make sure
ventilation open-
ings in the inverter
aren’t obstructed.
Reduce ambient
temperature

Maintenance

Very little maintenance is required to keep the invert-
er operating properly. The exterior of the unit should
be cleaned periodically with a damp cloth to prevent
accumulation of dust and dirt. At the same time,
tighten the screws on the DC input terminals. Be sure
vents and fans are free of dust or debris.

No output voltage

Short circuit

Check AC

or wiring

wiring for

error short

circuit

or

improper
polarity

Advertising