TROUBLE-SHOOTING CHART:

FAILURE

POSSIBLE CAUSE

1. Yellow light at switch does NOT light.

1a. Circuit breaker/fuse to wall outlet blown.

2a. Cord is unplugged from wall outlet.

3a. Switch is “OFF.”

2. Unit does not get hot.

2a. Thermostat set too low or are off.
2b. Switch is “OFF.”

3. Unit gets too hot or won’t shut off

3a. Defective electrical parts.
3b. UNPLUG UNIT FROM WALL OUTLET

4. Blower does not work or makes noise.

4a. Defective Blower

5. Excess moisture in cabinet.

5a. Foods taken from oven or fryer should be “slacked

out” for 5 minutes before placing in hot cabinet.

NOTE: Optional digital thermometer will fl ash if cabinet temperature is below 140°F or above 250°F.

Call the Factory if you need different settings.

If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.

REPLACEMENT PARTS:

CABINET PARTS:

DESCRIPTION

120 VOLT

240 VOLT

DESCRIPTION

PART NO.

Hot Unit

HU18671-184*

HU18671-185

Door Latch Kit

1006-143-K

Terminal Block

0852-091

0852-091

Latch Strike

1006-144-K

Blower Kit

0769-180-K

0769-182-K

Door Gasket, CCB-96A

0861-173

Heater Kit

0811-214-01

0811-215-01

Door Gasket, CCB-120A

0861-172

Thermostat Kit

0848-062-K

0848-062-K

Door Hinge

0519-084

Thermometer Kit

5238-030-K

5238-030-K

Push Handle

1072-089

Power Cord

0810-029-02*

0810-039-03

Wire Grid

1170-095

Switch Kit

0808-118-K

0808-118-K

Door Assembly, CCB-96A

1221-460-K

Door Assembly, CCB-120A 1221-461-K

For Canadian Use:*

Hot Unit (120 Volt)

HU18671-184C

Power Cord Plug

0713-017

Thermometer Kit, °C

5238-024-01